Section 3 of 5
Results and discussion
Nguyen Dang Thuy Anh, Vo Thi Cam Le, Huynh Van Chung, Ngo Thi Thanh Xuan, Hoang Thi Minh Nguyet, Pham Thi Thanh Ha, Ha Thuy Trang, Le Hoang Hao, Dao Thi Cam Minh, Nguyen Hai Phong, and Dinh Quang Khieu · about 31 minutes
Electrochemical synthesis of materials
Electrochemical preparation of electrodes
The electrochemical reduction of graphene oxide (GO) to electrochemically reduced graphene oxide (ErGO) was first investigated using cyclic voltammetry (CV). As shown in Figure 1a, a well-defined cathodic peak appears at approximately -1.49 V (vs. Ag/AgCl), corresponding to the irreversible reduction of oxygen-containing functional groups such as epoxy, hydroxyl, and carboxyl moieties on the GO sheets. The rapid decrease in peak intensity from the second cycle onward, accompanied by a slight shift toward more negative potentials, confirms the progressive depletion of reducible oxygen functionalities and the formation of a more stable ErGO structure [18]. The disappearance of the reduction peak in subsequent scans indicates the essentially irreversible nature of the GO reduction process. The electrodeposition of silver nanoparticles (AgNPs) was subsequently examined (Figure 1b). A distinct cathodic peak at approximately -0.12 V is attributed to the reduction of Ag⁺ ions to metallic silver according to: Ag+ + e- → Ag0. The pronounced crossover between forward and reverse scans suggests a typical nucleation and growth mechanism [19]. During the forward scan, the formation of initial Ag nuclei requires overcoming an energy barrier, resulting in relatively low current. In contrast, during the reverse scan, Ag deposition occurs preferentially on pre-formed nuclei, leading to a significantly enhanced current response. For the co-reduction system (Ag⁺-GO), two cathodic peaks are observed at approximately -0.28 and -1.46 V (Figure 1c), corresponding to the reduction of Ag⁺ and GO, respectively.

Figure 1.: 10 consecutive cyclic voltammograms for (a) electrochemical reduction of GO to ErGO; (b) electrodeposition of AgNPs and (c) reduction of Ag⁺ and GO to form AgNPs-ErGO composite . Inset: Magnified views of the cathodic scan showing the reduction of Ag⁺ ions in the potential range of 0.0 to -0.5 V (d) and the reduction of GO in the potential range of -1.0 to -2.0 V (e). Experimental condition for (a) and (c): scan rate: 100 mV s-1; step potential: 60 mV
This clearly indicates the simultaneous formation of AgNPs and ErGO. Compared with the individual systems, the reduction peaks become broader and less well-defined, which can be attributed to competitive adsorption and diffusion processes between GO sheets and Ag⁺ ions. The negatively charged GO sheets facilitate the elec-trostatic adsorption of Ag⁺, promoting nucleation and resulting in a homogeneous distribution of AgNPs on the ErGO matrix. This synergistic electrochemical process enables the in situ fabrication of the AgNPs-ErGO composite.
The electrochemical preparation of materials
The crystalline structures of GO, ErGO, and AgNPs-ErGO were characterized by X-ray diffraction (Figure 2a). The GO sample exhibits a characteristic diffraction peak at 2_θ_ ≈ 9.7°, assigned to the (001) plane, indicating an increased interlayer spacing due to oxygen functionalization. A weak peak at ~42.5° corresponds to the (100) plane of partially retained graphitic domains [20]. After electrochemical reduction, the (001) peak significantly diminishes and shifts to higher angles, while a broad peak emerges at ~24.6°, corresponding to the (002) plane of graphitic carbon [13,21]. This change indicates partial restoration of the sp2 carbon network and reduction of interlayer spacing. In the AgNPs-ErGO composite, additional diffraction peaks at 38.3, 44.5, 64.5 and 77.5° are observed, corresponding to the (111), (200), (220) and (311) planes of face-cantered cubic (fcc) silver (JCPDS 04-0783). The coexistence of these sharp peaks with the broad ErGO peak confirms the successful deposition of crystalline AgNPs onto the graphene matrix. Minor peaks associated with Ag₂O suggest slight surface oxidation of AgNPs.

Figure 2.: (a) XRD patterns; (b) FT-IR spectra; (c) Raman spectra of GO, ErGO and AgNPs-ErGO
FT-IR spectra (Figure 2b) provide insight into the surface chemistry and reduction process. GO shows characteristic absorption bands at ~3414 cm-1 (O-H stretching), 1721 cm-1 (C=O stretching), and 1051 to 1244 cm-1 (C-O vibrations), confirming a highly oxidized structure [22].
After reduction to ErGO, the intensity of oxygen-related bands significantly decreases, particularly the disappearance of the C=O peak, indicating effective removal of oxygen functionalities and restoration of conjugated carbon domains.
For the AgNPs-ErGO composite, slight shifts and intensity changes in characteristic bands are observed, suggesting interactions between AgNPs and residual oxygen-containing groups. These groups act as anchoring sites, stabilizing AgNPs and preventing aggregation.
Raman spectra (Figure 2c) show two prominent bands: the D band (~1351 cm-1) and the G band (~1595 cm-1). The _I_D/_I_G ratio increases from 0.84 (GO) to 1.10 (ErGO) and further to 1.20 (AgNPs-ErGO), indicating an increase in structural defects and disorder [13, 22].
This increase is associated with the removal of oxygen groups and the creation of new defect sites during reduction. The further increase in the composite suggests that the incorporation of AgNPs introduces additional defect sites or enhances Raman scattering. These defects are beneficial for electrochemical applications, as they provide active sites for electron transfer.
The morphology and elemental composition of the synthesized AgNPs-ErGO composite were investigated by EDX-mapping and TEM analyses (Figure 3). The elemental mapping images (Figures 3c to 3g) demonstrate the uniform distribution of C, O and Ag throughout the composite structure, confirming the homogeneous formation of the AgNPs-ErGO material.

Figure 3.: Morphological and elemental analysis of AgNPs-ErGO: a - SEM image; b - mapping image; elemental mapping images of: c - C, d - O, e - Ag, f - N and g - K; h - EDX spectrum and i - TEM image and particle size distribution histogram
The strong carbon signal originates from the graphene framework, while the oxygen signal suggests that a small number of oxygen-containing functional groups remain after the electrochemical reduction process. The silver signal is clearly and uniformly dispersed on the graphene surface, demonstrating that Ag nanoparticles were successfully immobilized without severe agglomeration. The EDX spectrum (Figure 3h) further confirms the elemental composition of the composite. The presence of intense Ag peaks with a relatively high content (22.85 wt.%) indicates the successful incorporation of silver nanoparticles into the ErGO matrix. The strong C signal confirms the graphene-based structure, whereas the O signal is associated with residual oxygen functionalities remaining on partially reduced graphene sheets. In addition, the presence of N and K may originate from residual impurities or precursor species that remain after synthesis and electrochemical treatment. The TEM image (Figure 3i) provides more detailed structural information about the AgNPs-ErGO composite. Transparent and thin graphene sheets with folded and corrugated structures are clearly observed, while dark spherical nanoparticles corresponding to AgNPs are distributed on the ErGO surface. The nanoparticles exhibit relatively uniform dispersion with nanoscale dimensions, suggesting that the ErGO sheets effectively prevent AgNPs aggregation and provide abundant nucleation sites during the deposition process [23]. Such a structural configuration is beneficial for electrochemical applications because the conductive ErGO network facilitates rapid electron transfer, whereas AgNPs provide abundant active catalytic sites, thereby enhancing the electrochemical sensing performance of the modified electrode.
Investigation and validation of the voltammetric method using a modified electrode for the determination of sibutramine adulterated in herbal weight-loss products
Investigation and selection of the modified electrode
Six types of electrodes were investigated in this study, including bare glassy carbon electrode (GCE), graphene oxide-modified GCE (GO/GCE), electrochemically reduced graphene oxide-modified GCE (ErGO/GCE), AgNPs-modified GCE (AgNPs/GCE), AgNPs-GO-modified GCE (AgNPs-GO/GCE) and AgNPs-ErGO-modified GCE (AgNPs-ErGO/GCE). The selection of a suitable working electrode was evaluated based on electron-transfer capability and electrochemically active surface area using the reversible redox probe [Fe(CN)₆]3-/4- (5 mM) in 0.1 M KCl solution (Figures S1 and S2, Supplementary material). The CV and EIS results of the six electrodes are presented in Figures 4a and 4b.
![Figure 4.: (a) Cyclic voltammograms and (b) Nyquist plots of six different electrodes: bare GCE, GO/GCE, ErGO/GCE, AgNPs/GCE, AgNPs-GO/GCE, and AgNPs-ErGO/GCE recorded in 5 mM [Fe(CN)₆]3-/4- containing 0.1 M KCl. (c) cyclic voltammograms of AgNPs-ErGO/GCE at different scan rates and (d) corresponding linear plots of anodic and cathodic peak currents vs. v1/2. Experimental conditions: potential range from -0.8 to +1.2 V and scan rate of 0.1 V s-1](/corpus-assets/pmc13499673.1/137d351eba718daa2861393ebe64568ca3ec9bd1c3acca3a16b3c510d939a219.webp)
Figure 4.: (a) Cyclic voltammograms and (b) Nyquist plots of six different electrodes: bare GCE, GO/GCE, ErGO/GCE, AgNPs/GCE, AgNPs-GO/GCE, and AgNPs-ErGO/GCE recorded in 5 mM [Fe(CN)₆]3-/4- containing 0.1 M KCl. (c) cyclic voltammograms of AgNPs-ErGO/GCE at different scan rates and (d) corresponding linear plots of anodic and cathodic peak currents vs. v1/2. Experimental conditions: potential range from -0.8 to +1.2 V and scan rate of 0.1 V s-1
As observed, the oxidation-reduction peak currents varied significantly with the modification layer on the GCE surface. Among them, GO/GCE exhibited the lowest peak current, whereas AgNPs-ErGO/GCE showed the highest current response. Electrodes containing ErGO, including ErGO/GCE and AgNPs-ErGO/GCE, displayed significantly higher peak currents than those containing unreduced GO. This result indicates that the reduction of GO to ErGO substantially improved the electrical conductivity of the material. To quantitatively evaluate the electrochemical performance of the electrodes, CV measurements were performed at scan rates of 0.020 to 0.400 V s-1 (Figure 4c). The linear relationships between the anodic/cathodic peak currents and the square root of scan rate (Figure 4d) were employed to estimate the electrochemically active surface area according to the Randles-Sevcik equation. The calculated values are summarized in Table 1.
Electrodes | A / cm2 | Ip,a/Ip,c ± SD / μA | ΔEP / V | Rct / Ω
Anode | Cathode
GCE | 0.042 | 0.043 | 1.06 ± 0.05 | 0.40 ± 0.11 | 128
GO/GCE | 0.007 | 0.007 | 1.01 ± 0.04 | 0.16 ± 0.02 | 953
ErGO/GCE | 0.034 | 0.034 | 1.02 ± 0.02 | 0.19 ± 0.05 | 730
AgNPs/GCE | 0.037 | 0.039 | 0.93 ± 0.01 | 0.32 ± 0.11 | 345
AgNPs-GO/GCE | 0.027 | 0.027 | 0.95 ± 0.02 | 0.20 ± 0.04 | 968
AgNPs-ErGO/GCE | 0.045 | 0.046 | 1.03 ± 0.02 | 0.30 ± 0.08 | 441
It appears partially contradictory in Table 1. For example, the bare GCE exhibited the lowest charge-transfer resistance (_R_ct = 128 Ω), which would normally suggest the fastest electron-transfer process. However, this electrode exhibited the largest peak-to-peak separation (Δ_E_p = 0.40 V), indicating relatively slow electrochemical kinetics during cyclic voltammetry.
In contrast, GO/GCE and ErGO/GCE displayed much larger _R_ct values but significantly smaller Δ_E_p values. This apparent inconsistency arises because EIS, Δ_E_p, _I_p,a/_I_p,c, and electrochemically active surface area (ECSA) reflect different aspects of the electrochemical process and are influenced by different physicochemical factors. The low _R_ct value of bare GCE mainly reflects the excellent intrinsic conductivity and compact surface structure of the glassy carbon electrode under near-equilibrium EIS conditions. However, the relatively smooth and chemically inert surface of bare GCE offers a limited number of electroactive sites, leading to a larger Δ_E_p despite its low interfacial resistance. This interpretation is supported by the _I_p,a/_I_p,c ratio of 1.06 ± 0.05, which remains close to unity and indicates acceptable reversibility, although the electron-transfer kinetics during dynamic potential scanning are still relatively slow. For GO/GCE, the situation is opposite. The ECSA dramatically decreased to ~0.007 cm2 and the _R_ct increased sharply to 953 Ω due to the intrinsically poor conductivity of GO caused by abundant oxygen-containing functional groups disrupting the conjugated carbon network. Nevertheless, GO/GCE exhibited a remarkably small Δ_E_p value (0.16 V) and an _I_p,a/_I_p,c ratio close to unity (1.01 ± 0.04). This suggests that although bulk electron transport through the GO layer is hindered, the oxygenated functional groups and structural defects on GO can promote surface-mediated redox interactions and facilitate apparent electrochemical reversibility during CV measurements. After electrochemical reduction, ErGO/GCE showed partially restored conductivity, reflected by a lower _R_ct value (730 Ω) compared with GO/GCE and an increased ECSA (0.034 cm2). Simultaneously, the Δ_E_p remained relatively small (0.19 V) and the _I_p,a/_I_p,c ratio stayed close to unity (1.02 ± 0.02), indicating improved reversibility and electron-transfer kinetics. This behaviour can be attributed to the recovery of the π-conjugated sp2 carbon network after reduction, which enhances conductivity while preserving defect sites and surface roughness favourable for electrochemical reactions [24]. The incorporation of Ag nanoparticles further complicated the electrochemical behaviour. AgNPs/GCE exhibited a relatively low _R_ct (345 Ω) and a high ECSA, demonstrating the conductive and electrocatalytic role of AgNPs. However, the _I_p,a/_I_p,c ratio slightly decreased to 0.93±0.01, suggesting some degree of surface heterogeneity or adsorption effects induced by AgNPs. In AgNPs-GO/GCE, the Δ_E_p remained small (0.20 V) despite the very high _R_ct value (968 Ω), again confirming that Δ_E_p and _R_ct are not directly proportional. Here, the redox-active defect sites and surface functionalities of GO likely improved apparent reversibility, whereas the insulating character of GO still dominated the interfacial resistance measured by EIS [25]. Among all electrodes, AgNPs-ErGO/GCE exhibited the best balance of electrochemical properties, with the highest ECSA (0.045-0.046 cm2), an _I_p,a/_I_p,c ratio close to unity (1.03 ± 0.02), and moderate Δ_E_p and _R_ct values. The synergistic combination of conductive ErGO sheets and electrocatalytically active AgNPs created a highly accessible electroactive surface that facilitated charge transfer and improved reversibility. Therefore, the apparent contradictions in Table 1 arise because EIS and CV characterize different electrochemical phenomena. _R_ct obtained from EIS mainly reflects interfacial electron-transfer resistance under near-equilibrium conditions, whereas Δ_E_p and _I_p,a/_I_p,c are additionally influenced by active surface area, adsorption behaviour, surface heterogeneity, and mass transport during dynamic potential scanning. Consequently, the electrochemical performance of the electrodes should be interpreted based on the combined effects of conductivity, electroactive surface area, and electrocatalytic activity rather than a single parameter alone.
Investigation of material ratio and modifier loading
The ratio between AgNPs and GO strongly influenced the electrochemical response toward SIB oxidation (Figures 5a and 5b). As the AgNPs:GO ratio varied from 1:3 to 1:10, noticeable changes in the LSV responses were observed. At the 1:3 ratio, the background current increased significantly because the higher AgNPs content improved the electrical conductivity of the modified layer.

Figure 5.: (a) Linear sweep voltammograms of sibutramine obtained at AgNPs-GO modified electrodes with different AgNPs:GO ratios and (b) corresponding variation of oxidation peak current (IP). (c) LSV responses and (d) variation of oxidation peak current of sibutramine at different loading volumes of AgNPs-GO composite (AgNPs:GO = 1:5, w/w). Experimental conditions: Eacc (accumulation potential) = -0.2 V, tacc (accumulation time) = 120 s, scan rate = 0.100 V s-1, 0.05 M BR buffer solution (pH 7) and CSIB = 9.9 mg L-1
However, the oxidation peak current in SIB did not reach its maximum. Increasing the GO content to a 1:5 ratio resulted in a substantial enhancement in the oxidation peak current, reaching a maximum of approximately 32 μA. This behaviour suggests that the 1:5 ratio provides an optimal balance between the excellent conductivity of AgNPs and the adsorption capability of GO. When the GO content was further increased to 1:10, the peak current slightly decreased, likely due to the restacking of GO sheets, which hindered electron transfer and mass diffusion. Therefore, the AgNPs:GO ratio of 1:5 was selected for further experiments. The effect of modifier loading was also investigated in the range of 2-10 μL (Figure 5c-d). Increasing the deposited volume from 2 to 4 μL significantly increased the oxidation peak current due to the increased number of electroactive sites on the electrode surface. However, when the loading exceeded 4 μL, the current response gradually decreased. This phenomenon can be attributed to the formation of an excessively thick modifier film, which increases diffusion resistance and hinders electron-transfer processes. Consequently, a loading volume of 4 μL was selected as the optimal condition for electrode fabrication.
Effect of pH and scan rate
The pH of the supporting electrolyte plays a crucial role in determining the protonation state of SIB and the electron-transfer kinetics at the modified electrode surface (Figure 6a). When the pH increased from 3.0 to 7.0, the oxidation peak current gradually increased, reaching a maximum at pH 7.0 with an Ip of 40.40 ± 0.12 μA. This result indicates that neutral conditions favour the electrochemical oxidation of SIB. Further increasing the pH to 8.0 led to a sharp decrease in current response, which may be associated with changes in the protonation state of SIB and weaker interactions with the electrode surface. Therefore, pH 7.0 was selected as the optimal condition for quantitative analysis (Figure 6b).

Figure 6.: (a) Linear sweep voltammograms of SIB recorded at different pH values, (b) variation of oxidation peak current (IP) as a function of pH, and (c) linear relationship between oxidation peak potential (EP) and pH at the AgNPs-ErGO/GCE electrode. Experimental conditions: Eacc = -0.2 V, tacc = 120 s, scan rate = 0.100 V s-1, 0.05 M BR buffer solution and CSIB = 9.9 mg L-1
In addition, the oxidation peak potential (_E_p) shifted linearly toward less positive values with increasing pH, indicating the direct involvement of protons in the electrochemical oxidation process (Figure 6b). The linear regression Equation (1) was obtained.

The slope value (~0.062 V pH-1) is close to the theoretical Nernstian value, suggesting that the number of protons and electrons involved in the reaction is equal (p/n = 1). Therefore, the electrochemical oxidation of SIB at the AgNPs-ErGO/GCE electrode can be considered a proton-coupled electron-transfer process.
The influence of scan rate on the electrochemical behaviour of SIB was investigated by cyclic voltammetry over the range of 0.010 to 0.300 V s-1 (Figure 7a). As the scan rate increased, the oxidation peak current increased, indicating accelerated electrochemical kinetics. A good linear relationship between _I_p and _v_1/2 was obtained with _R_2 = 0.9901 (Equation 2) (Figure 7b), demonstrating that the mass-transfer process of SIB is strongly influenced by diffusion [26, 27].


Figure 7.: (a) Cyclic voltammograms of SIB at the AgNPs-ErGO/GCE electrode recorded at different scan rates, (b) linear relationship between IP and v1/2, (c) linear plot of ln IP vs. ln(v) and (d) relationship between Ep and ln(v). Experimental conditions: Eacc = -0.2 V, tacc = 120 s, scan rate = 0.100 V s-1, 0.05 M BR buffer solution (pH 7) and CSIB = 19.6 mg L-1
Moreover, the linear relationship between ln(_I_p) and ln(v) yielded a slope value of 0.803 (Equation 3) (Figure 7c), which lies between the theoretical values of 0.5 (diffusion-controlled process) and 1.0 (adsorption-controlled process) [28]. This result suggests that the electrochemical oxidation of SIB at the AgNPs-ErGO/GCE electrode follows a mixed diffusion-adsorption controlled mechanism.

When investigating the effect of scan rate by cyclic voltammetry (CV) (Figure 7d), the results showed that the electrochemical oxidation of SIB at the modified electrode surface was not governed exclusively by diffusion or adsorption but rather followed a mixed-controlled mechanism involving both processes. However, the adsorption component appeared to play a dominant role. These findings indicate that SIB molecules are not only transported from the bulk solution to the electrode surface by diffusion but also interact with and accumulate on the modified electrode surface prior to electron transfer.
These observations are consistent with trends reported in previous studies. Specifically, Teradal et al. [29], in their investigation of SIB oxidation at an ErGO/GCE electrode, observed two irreversible oxidation peaks: the first was adsorption-controlled, whereas the second was diffusion-controlled. Similarly, Lima et al. [30], using a screen-printed electrode, reported that the first oxidation peak current of SIB increased linearly with scan rate, indicating that the process was predominantly adsorption-controlled. The authors further emphasized that this mechanism differed from that observed at boron-doped diamond (BDD) electrodes, where the mass-transfer process was mainly diffusion-controlled [31]. In addition, Shi et al. [12], using an MIP-rGO modified GCE electrode, reported that the slope of the regression equation between ln _I_p and ln v was approximately 0.76, suggesting that the electrochemical oxidation of SIB was controlled by a mixed adsorption-diffusion mechanism.
The large surface area and abundant active sites of ErGO likely facilitate the accumulation of SIB molecules at the electrode surface during the preconcentration step. The electron-transfer coefficient (α) was estimated from the relationship between _E_P and _E_P/2 (Equation (4)) and was calculated to be approximately 0.47, which is close to the theoretical value of 0.5 for an irreversible electrochemical process [32].

This result confirms that the oxidation of SIB on the AgNPs-ErGO/GCE electrode is electrochemically irreversible. To determine the heterogeneous electron-transfer rate constant (_k_⁰), it is necessary to calculate the formal redox potential (_E_⁰′). The determination of _E_⁰′ was based on the dependence of the oxidation peak potential (_E_p) on the scan rate (v). By extrapolating the _E_p versus v relationship to v = 0, the value of _E_⁰′ can be obtained. Experimental results revealed a nonlinear relationship, Equation (5).

From this relationship, the formal potential _E_⁰′ was determined to be +0.463 V vs. Ag/AgCl|3 M KCl reference electrode.
Subsequently, based on the relationship between _I_p and (_E_p - _E_⁰′), Equation (6) was applied:

where F: the Faraday constant (96,485 C mol−1); _K_0: heterogeneous electron-transfer rate constant. Using the values of electrode area A = 0.046 cm2 and analyte concentration _C_₀ = 58.7 μM, the heterogeneous electron-transfer rate constant _k_⁰ was calculated to be 195.2 s-1. This result indicates that the electron-transfer process in SIB at the AgNPs-ErGO/GCE-modified electrode is relatively fast.
Based on the above findings, together with previously reported studies on the electrochemical oxidation of tertiary amine groups [33], the oxidation mechanism of SIB at the AgNPs-ErGO/GCE electrode is proposed as follows. In a BR buffer solution at pH 7, the nitrogen atom of the dimethylamine group uses its lone pair of electrons to bind a proton (H⁺) in solution. Consequently, more than 99 % of SIB molecules exist in the protonated cationic form (SIB-H⁺). This protonated species represents the initial state of the analyte as it approaches the electrode surface.
The investigation of the pH effect on the oxidation peak potential (_E_P) mentioned above indicates that the number of electrons and protons involved in the electrochemical reaction is equal. For SIB, this process is typically associated with the oxidation of the tertiary amine group involving the transfer of one electron and one proton.
To simultaneously satisfy both the Nernstian behaviour (1e⁻/1H⁺) and the initial protonated state of SIB, the oxidation mechanism is proposed to proceed as follows: the reaction initially involves a fast chemical pre-equilibrium step in which the protonated species SIB-H⁺ rapidly dissociates to generate a small amount of neutral free-base SIB along with the release of a proton (H⁺) into the solution (Scheme 1). Subsequently, during the electrochemical step, the nitrogen atom of the free-base SIB donates one electron from its nonbonding lone pair to the electrode surface, leading to the formation of a relatively stable aminium radical cation (N•⁺) (Scheme 2). The continuous electrochemical consumption of free-base SIB at the electrode surface drives the chemical equilibrium strongly toward the forward direction. The obtained results, indicating that the electrochemical oxidation of SIB involves the transfer of one electron (1e⁻) and one proton (1H⁺) from the protonated tertiary amine group, are in good agreement with most previously reported studies (Scheme 3), including those published by Freitas et al. [31], Sirivibulkovit et al. [34], and Kongsuwan et al. [35], who proposed similar oxidation mechanisms for SIB using various modified electrodes.

Scheme 1.: Chemical equilibrium between SIB and protonated SIB-H⁺ in the supporting electrolyte solution

Scheme 2.: Proposed oxidation process of SIB at the electrode surface

Scheme 3.: Overall proposed electrochemical oxidation mechanism of SIB at the AgNPs-ErGO/GCE.
Optimizing operational parameters
The instrumental parameters, including accumulation potential (_E_acc), accumulation time (_t_acc), and linear sweep scan rate (_v_LSV), were systematically investigated to determine the optimal experimental conditions (Figs. S3-S5). The results revealed that _E_acc = 0 V, _t_acc = 150 s, and _v_LSV = 0.1 V s-1 provided the most stable and highest current response. Therefore, these conditions were selected for all subsequent electrochemical measurements.
Method validation
Specificity
The voltammetric responses of the supporting electrolyte solution (0.05 M BR buffer, pH 7), placebo sample, and placebo samples spiked with SIB at three concentration levels of 2.0, 3.9 and 5.9 mg L-1 were recorded. The obtained results are presented in Figure 8a. In the voltammograms of the supporting electrolyte solution (black curve) and the placebo sample (blue curve), no oxidation peak was observed in the potential range of 0.4-0.8 V. However, after spiking SIB into the placebo matrix at increasing concentrations (from 2.0to 5.9 mg L-1), a well-defined oxidation peak clearly appeared at approximately +0.62 V. The oxidation peak current (_I_p) increased proportionally with increasing SIB concentration. In addition, the peak obtained was sharp, symmetrical, and completely separated from the background current, indicating good selectivity of the proposed method for SIB detection.

Figure 8.: (a) LSVs of the supporting electrolyte, standard SIB solution, placebo sample and placebo samples spiked with different concentrations of SIB under the following experimental conditions: Eacc = 0 V, tacc = 150 s, v = 0.100 V s-1, 0.05 M BR buffer solution, and pH 7; (b) LSV responses obtained at different SIB concentrations and (c) corresponding calibration plot between Ip,SIB and CSIB (inset: CSIB = 2.0 to 9.9 mg L-1), experimental conditions: Eacc = 0 V, tacc = 150 s, scan rate = 0.100 V s-1, 0.05 M BR buffer solution, pH 7
Regarding signal deviation, at CSIB = 2.0 mg L-1, the obtained residual standard deviation (RSD) value was 4.93 %, which is lower than the 1/2RSDH value (7.16 %), where RSDH represents the RSD estimated from the Horwitz function. At _C_SIB = 3.9 mg L-1, the RSD value was 4.11 %, lower than the corresponding 1/2RSDH value of 6.48 %. Similarly, at C_S_IB = 5.9 mg L-1, the RSD value was 3.90 %, which was also lower than the corresponding 1/2RSDH value of 6.09 %. At all investigated concentration levels, the experimental RSD values were lower than the corresponding 1/2RSDH. These results demonstrate that the proposed method exhibits high selectivity and satisfactory analytical performance for detecting SIB in complex sample matrices [36].
Linear range and limit of detection
The concentration of the standard SIB solution in the electrochemical cell was varied from 2.0 mg L-1 to 33.8 mg L-1. The corresponding linear range investigation is presented in Figure 8b-c. The obtained results demonstrate that the oxidation peak current exhibited a good linear correlation with the concentration of SIB in the range from 2.0 to 14.8 mg L-1 according to Equation (7):

When the SIB concentration was further increased to 33.8 mg L-1, the increase in _I_P,SIB became slower and less significant (Figure 8c), suggesting a tendency toward signal saturation at higher concentrations. However, to accurately establish the linear range of the method, the limit of detection (LOD) and limit of quantification (LOQ) were further evaluated. Since the determination of LOD is typically performed using concentrations close to the origin, the concentration range from 2.0 to 9.9 mg L-1 was selected for subsequent analysis (inset of Figure 8c). The corresponding calibration is given by equation (8)

The LOD and LOQ values were calculated based on the slope of the calibration curve and the standard deviation of the analytical signal. The obtained values were 0.56 mg L-1 (or 1.7 μM) for LOD and 1.85 mg L-1 for LOQ. The calculated LOD satisfied the conditions of 10 LOD >_C_min and LOQ < _C_min [37]. Therefore, the linear range for the electrochemical determination of SIB was established from 1.85 to 14.8 mg L-1.
Table 2 compares the analytical performance of the proposed AgNPs-ErGO/GCE electrode with previously reported electrochemical methods for sibutramine determination. The LOD obtained in the present study (1.7 μM) is higher than those reported for several advanced electrochemical sensors, such as MIP/RGO-GCE (0.02 μM), Na/P-CNTs/GCE (0.03 μM), ERGO/GCE (0.048 μM), and N-GNF@f-CNT/SPE (0.01 μM). The high sensitivity of these previously reported electrodes can be attributed to the use of highly porous nanostructured materials, molecularly imprinted polymers (MIPs), heteroatom-doped carbon materials, or adsorptive stripping techniques, which significantly enhance analyte preconcentration and electron-transfer efficiency.
Electrodes | Method, pH | Linear range, μM | LOD, μM | Sample | Ref.
HMDE | DPV, 4.0 | 4.2 to 99.6 | 1.2 | Energy drinks, green tea and pharmaceutical formulations | [38]
ERGO/GCE | DPV, 8.0 | 0.250 to 20.0 | 0.048 | Human serum and urine samples | [29]
BDD | SWV, 0.1 M H₂SO₄ | 15 to 149.6 | 0.2 to 5.8 | Herbal formulations and dietary supplements samples | [31]
SPE-Gr | AdSDPV, 7,0 | 2.0 to 120 | 0.3 | Slimming tea beverage | [30]
PGr-ink/GCE | SWAdSV, 8.0 | 0.04 to 29.9 and29.9 to 149.6 | 0.01 | Illegal slimming product | [39]
ePAD | SWV, 4.0 | 7.5 to 250.4 | 7.4 | Capsules, slimming coffee powders and nutraceutical beverages | [34]
Na/P-CNTs/GCE | AdASV, 8.0 | 0.07 to 59.8 and59.8 to 179.5 | 0.03 | Weight-loss products | [35]
MIP/RGO-GCE | DPV, 6.5 | 0.05 to 20 | 0.02 | Human urine and serum samples | [12]
N-GNF@f-CNT/SPE | SWASV, 7.0 | 0.03 to 29.9 and29.9 to 179.5 | 0.01 | Food supplements | [40]
AgNPs-ErGO/GCE | LSV, 7.0 | 5.5 to 44.3 | 1.7 | Herbal weight-loss products | This study
Nevertheless, the proposed AgNPs-ErGO/GCE electrode still delivers satisfactory analytical performance for practical screening applications, particularly for herbal slimming products, where sibutramine is often present at relatively high concentrations. The obtained linear range (5.5 to 44.3 μM) is comparable to or broader than several previously reported methods, including HMDE, BDD and ePAD-based sensors. In addition, although some studies reported lower detection limits, many of those methods require more complicated fabrication procedures, expensive electrode materials, or sophisticated sensing architectures such as molecular imprinting and dual-doped nanocarbon systems.
In contrast, the AgNPs-ErGO/GCE electrode developed in this study offers several practical advantages, including simple preparation, low-cost materials, rapid electrode fabrication through electrochemical synthesis, and satisfactory repeatability and accuracy. The synergistic combination between AgNPs and ErGO effectively improves the electroactive surface area and electron-transfer kinetics, enabling reliable determination of sibutramine in complex herbal matrices. Although it does not offer the lowest LOD among reported methods, the proposed sensor demonstrates strong potential as a simple, rapid, and cost-effective electrochemical platform for routine screening of SIB adulteration in herbal weight-loss products.
Intra-day precision
The intra-day precision of the stripping peak current signal (_I_P) was evaluated at three concentration levels of 4.0, 9.9, and 15.8 mg L-1, Figure 9. The experimentally obtained _I_p and RSD values were compared with the corresponding 1/2RSDH values calculated from the Horwitz equation [36].

Figure 9.: Linear sweep voltammograms of SIB obtained from nine replicate measurements at different concentrations: (a) CSIB = 4.0 mg L-1, (b) CSIB = 9.9 mg L-1, and (c) CSIB = 15.8 mg L-1. Experimental conditions: Eacc = 0 V, tacc = 150 s, scan rate = 0.100 V s-1, 0.05 M BR buffer solution, and pH 7
The repeatability results showed that at _C_SIB = 4.0 mg L-1, the relative standard deviation (RSD) was 3.95 % compared with 1/2RSDH = 6.48 %. At _C_SIB = 9.9 mg L-1, the RSD value was 3.46 %, lower than 1/2RSDH = 5.63 %. Similarly, at _C_SIB = 15.8 mg L-1, the obtained RSD value was 4.18 %, lower than 1/2RSDH = 5.25 %. At all investigated SIB concentrations, the experimental RSD values were smaller than the corresponding 1/2RSDH values, indicating that the proposed electrochemical method satisfies the repeatability requirement for _I_p measurements.
Inter-day precision
The inter-day precision of the proposed method was evaluated by independently preparing modified electrodes using the synthesized material and recording the voltammetric response of standard SIB solutions by the LSV technique on different days. After each measurement, the modified film on the electrode surface was completely removed by polishing the electrode with 0.03 μm Al₂O₃ powder, followed by re-modification according to the same fabrication procedure. This process was repeated five times under identical experimental conditions. The obtained results are presented in Figure 10.

Figure 10.: (a) Linear sweep voltammograms and (b) variation of the oxidation peak current (Ip) of SIB obtained from five independently prepared AgNPs-ErGO/GCE modified electrodes
Recovery
Standard SIB solutions were spiked into the placebo matrix at three concentration levels of 2.0, 3.9 and 5.9 mg L-1, followed by recording the corresponding voltammetric responses. The analysis was performed in triplicate at each concentration level. The accuracy of the proposed LSV method using the AgNPs-ErGO/GCE-modified electrode was evaluated based on recovery values (Rev, %) [41]. Subsequently, SIB was spiked into the samples at three concentrations of 1.976, 3.945 and 5.906 mg L-1. The quantitative determination of SIB was then carried out using the LSV method with the AgNPs-ErGO/GCE-modified electrode, and the results obtained are summarized in Table 3.
Measurement No | Spiked CSIB / mg L-1
1.976 | 3.945 | 5.906
Found CSIB / mg L-1 | Rev, % | Found CSIB / mg L-1 | Rev, % | Found CSIB / mg L-1 | Rev, %
1 | 1.779 | 90.03 | 3.502 | 88.78 | 6.107 | 102.4
2 | 1.828 | 92.52 | 3.782 | 95.88 | 6.089 | 103.1
3 | 1.817 | 91.94 | 3.724 | 94.39 | 5.461 | 92.48
Average | 1.808 | 91.50 | 3.669 | 93.02 | 5.886 | 99.67
SD | 0.026 | 1.303 | 0.148 | 3.741 | 0.368 | 6.227
The recovery values obtained for SIB at the three investigated concentration levels ranged from 88.78 to 103.1 %. These results meet the acceptable recovery criteria recommended by the AOAC guidelines (80 to 110 %) [41], indicating that the proposed method is accurate.
Real sample analysis
The developed analytical method was applied to quantify sibutramine adulterated in several herbal-based weight-loss products collected from the market
A total of 30 herbal-based weight-loss products currently available in Vietnam were collected from different market sources. These samples included 24 capsules, 3 tablets, 1 powder, and 2 tea bags. The concentration of sibutramine in the samples was determined using the standard addition method. The SIB content, mg g-1 in each sample, was calculated according to Equation (9):

where a / μA and b / mg mL-1 are the intercept and slope of the linear regression equation, respectively; _V_Cell = 10 mL is the volume of the electrochemical cell; _V_0 / mL is the volume of methanol used to dissolve the sample (solution A); _V_1 / mL is the aliquot volume of solution A taken for dilution; _V_2 / mL is the final volume after dilution (solution B); _V_3 / mL is the volume of solution B introduced into the electrochemical cell for analysis and _m_0 / g is the initial sample mass. The analytical results obtained from 30 collected herbal-based weight-loss products revealed that seven samples, namely #1, #2, #3, #4, #5, #6 and #7, were illegally adulterated with sibutramine. The proposed LSV method was applied for the determination of SIB in real samples, and the obtained results were compared with those from the reference HPLC-DAD method (Table 4).
Samples | Content, mg g-1
LSV | HPLC-DAD
#1 | 36.20 | 35.53
#2 | 42.77 | 42.80
#3 | 33.23 | 32.99
#4 | 66.61 | 64.83
#5 | 29.28 | 30.70
#6 | 24.41 | 23.72
#7 | 35.78 | 36.95
The results obtained from the proposed LSV method with the AgNPs-ErGO/GCE-modified electrode and the HPLC-DAD method were statistically compared using a paired-samples t-test, where t denotes the Student's t-statistic. The analysis revealed no statistically significant difference between the mean values obtained by the two methods (t(6) = 0.258, p = 0.805). These results demonstrate that the proposed LSV method based on the AgNPs-ErGO/GCE-modified electrode possesses satisfactory accuracy and reliability and can be considered a promising alternative analytical approach for determining SIB in herbal-based weight-loss products.